White Bar
Fireworks Display

Fireworks Display

Worksheet

The following worksheet must be filled out and turned in to the BYU-Idaho Safety Office 24 hours prior to the date of the display.                                                                  For Office Use

 

¨  Site plan drawing

o   Dimensions of discharge site

o   Spectator viewing area

o   Parking area’s

o   Debris fallout area

o   Associated separation distances

¨ Radius of the display area must be 70’/1” of shell size

o   No spectator viewing area’s within the display site

o   No spectator parking within the display site

¨ Buildings within display area or fallout area

o   Must be shown on site plan

o   Must have fire watch on and around the building

o   Must have prior approval of the building owner/BYU-Idaho Safety Office

¨ Display and Fallout area

o   Must be properly marked (Do Not Cross Tape)

o   Display area must be properly secured so as to allow no unauthorized personnel into the area

¨ Personnel

o   Must have proper PPE

o   Must be in place before Fireworks can begin

o   Must have proper firefighting equipment

o   Must have designated escape routes

¨ Ground fireworks must be a minimum of 75’ from spectator viewing area’s and parking area’s

¨ The trajectory of aerial shells must not come within 25’ of any overhead object

Figure A.3.2.3 illustrates some of the requirements for a permitted display site where mortars are placed vertically, such as might be the case for an electrically ignited display.

Text Box: Date Submitted_______________
Signatures
Responsible party_______________________
 
Safety Office___________________________
 
Permit #_______________________________
Permit must be attached to this document

 

 

 

 

 

 

 

 

 

                                                                                                                                                               

 

 

 

 

 

 

 

  Text Box: Vertical mortars and center of fall out area.
(Non-angled mortars)
Text Box: Minimum secured distance from center of Display Site
70’per every inch of shell
Example: 3” Shell = 210’

 

Figure A.3.2.3 Typical layout for a display site with vertically positioned mortars.